Combustion Exhaust Blower Features
- 85 CFM Blower
- Replaces existing combustion exhaust blower on Englander pellet stoves
- Complete assembly with gasket and pipe adapter included
- Includes wire leads for fast “plug and play” installation
- Round Gasket Included.
- Not compatible with Englander model 25-PUF or 10-CPM multi-fuel stove
-
The blower comes with one male and one female wire and connector. It also comes with one male to male connector and one female to female connector to accommodate all types of installs.
Instructions For Replacing The Blower
To replace the Combustion (exhaust) Blower (Part # PU-076002B), the power leads and the pellet vent pipe must be disconnected. Next, remove the screws that hold the blower to the steel exhaust tube and slide the blower from the stove. Note: There is a Combustion Motor Gasket (Part # PU-CMG), which allows you to remove the motor from the Combustion Blower housing, clean your stove, and replace the motor and gasket without having to remove the entire Combustion Blower. If cleaning your blower, the blower impeller, blower tube and steel blower exhaust tube on the unit should be brushed and vacuumed. However, if you must remove or replace the entire Combustion Blower, a new blower flange gasket (Part # PU-CBG) should be added between the blower flange and the steel exhaust tube.